Dock door simulator

Drive a tagged pallet past two dock doors and watch what each reader hears, which reads the rules keep, and what the system concludes: which door, which direction, or nothing.

staging lanedoor 1door 2
Top down, trucks at the bottom. Teal shading is where a reader can hear the tag; the darker band is where it passes the RSSI floor. Drag the time slider or press play. Geometry is illustrative: doors 6 m apart, the lane 8.5 m back, forklift at 1.5 m/s.
The reader
The rules

At -90 nothing is ignored: that's below what either reader can hear.

AntennaReadsPeakSeenCounted

Free space plus the antenna's pattern and the panels; no reflections. In a real dock the same tag swings 10 dB either way as a truck pulls in, so a rule that works here by 3 dB will not work there. How a read works and the range calculator have the link budget behind it.

Door 1 reads a pallet that left through door 2. It heard it in the staging lane, 8 m back, at -66 dBm. The reader hears down to -88.

What you’re looking at

A dock from above. Two doors, 6 m apart, each with a reader antenna on the frame pointing into the building. A staging lane runs across the back, 8.5 m from the wall, and the forklift drives along it at 1.5 m/s before turning down to a door.

The reader at door 1 sends 1 W to an antenna that points straight down the lane. A pallet driven along the lane behind it is on axis, 8 m away, and its tag answers at about -66 dBm. The reader can hear down to -88. That’s a read, a good one, of a pallet that then leaves through door 2. A pallet parked in the lane does the same thing continuously.

The rules on the right are the ones real deployments use, and the simulator shows what each fixes and what it leaves. Lower power and a steeper tilt take the lane pass from -66 to the high -70s, which this reader still hears. Absorber panels on the portal’s sides stop door 1 from hearing a pallet heading into door 2, and do nothing for a pallet on axis. A floor of -60 dBm throws away all of them in free space. In a real dock the same tag swings 10 dB either way as a truck pulls in, so a rule that works here by 3 dB does not work there.

The two that change what the system concludes are the second antenna and the sensor. Two antennas on a door, one facing in and one facing the truck, tell you direction from which saw the tag first. A sensor gate only counts reads within a few seconds of a beam break, so a parked pallet, or one in the next lane, produces no event at all.

What it assumes

Free space, plus three stated penalties: the antenna’s pattern (a 70° beam, a textbook parabola capped at 20 dB front-to-back) in the horizontal and the vertical, and 20 dB each way for a tag behind the absorber panels. Antennas 1.5 m above the tag. No reflections off trucks, racking or the floor, which is the biggest thing a real dock adds. The NXP UCODE 9 chip from the range calculator, a half-wave dipole tag, a 6 dBi circular antenna, 1 dB of cable, 6 dB of backscatter loss. That is 35 dBm EIRP at full power, just inside India’s limit of 2 W ERP (35.15 dBm EIRP); the 2021 rules replaced the old 1 W-at-the-reader rule, and a higher-gain antenna would mean turning the reader down. Dropping to 0.25 W is 6 dB less. Ten reads a second per antenna, and an event needs at least three reads.

The geometry is illustrative. Your dock has different spacings, and the panel loss depends on the panel.

Where the numbers come from

Reader sensitivities are Impinj’s datasheet figures for the E710 (dense-readers mode, -88 dBm) and E310 (fast mode, -71 dBm). The link budget is the one in Wake the tag and the range calculator; the pattern model and the panel penalty are stated above rather than measured. The film uses the same sums, so its figures and this page’s agree.