Free tool
WIP read-point planner
List the stations a job goes through. See where the readers go, what event each one writes into the order history, and how many tags you need.
Plan your read points
5 stations, 6 antennas, 150 tags. Where is 4417 at 15:30? In Grinding, since 14:50.
- Cuttingdesk pad
- in
- out
- Turningdesk pad
- in
- out
- Heat treatmentgate
- in
- out
- Grindingdesk pad
- in
- out
- Inspectiondesk pad
- in
- out
- Gates (two antennas each)
- 1
- Desk pads
- 4
- Readers, one per station
- 5
- Tags: inlay on the side of the bin
- 150
- Tag spend, once
- ₹750 to ₹1,200
What each read point says
| Station | Antenna | Event | EPCIS bizStep |
|---|---|---|---|
| Cutting | Desk pad, first heard | 4417 arrived at Cutting | arriving |
| Cutting | Same pad, gone quiet | 4417 left Cutting | departing |
| Turning | Desk pad, first heard | 4417 arrived at Turning | arriving |
| Turning | Same pad, gone quiet | 4417 left Turning | departing |
| Heat treatment | Entry gate antenna | 4417 entered Heat treatment | arriving |
| Heat treatment | Exit gate antenna | 4417 left Heat treatment | departing |
| Grinding | Desk pad, first heard | 4417 arrived at Grinding | arriving |
| Grinding | Same pad, gone quiet | 4417 left Grinding | departing |
| Inspection | Desk pad, first heard | 4417 arrived at Inspection | arriving |
| Inspection | Same pad, gone quiet | 4417 left Inspection | departing |
Order 4417, an example day
- 4417 arrived at Cutting
- 4417 left Cutting
- 4417 arrived at Turning
- 4417 left Turning
- 4417 entered Heat treatment
- 4417 left Heat treatment
- 4417 arrived at Grinding
| Station | Waiting before it | At it |
|---|---|---|
| Cutting | first station | 50 min |
| Turning | 20 min | 1 h 32 |
| Heat treatment | 30 min | 2 h 33 |
| Grinding | 1 h 35 | 40 min |
Example times, not a measurement. At every station, "at it" is queue and work together. Add a start pad where you need them apart.
How it works
What you’re looking at
A job moves through your stations in a bin, on a trolley, or with a job card. Put one tag on that, and a read point at each station, and the order’s history writes itself: which station it reached, when, and when it left.
There are two kinds of read point here.
A desk pad is a small antenna under the spot where the job card or the bin is put down. It goes down when the job arrives and is picked up when it leaves, so one pad gives you both. The edge decides the job has gone when the pad hasn’t heard its tag for a while, the same way a dock door decides a pallet has left in part 12 of the series.
A gate is two antennas a trolley rolls past, one at the way in and one at the way out. It suits a station the trolley goes through whole, like a furnace or a paint line.
Either one can get a start pad: a second pad at the machine. Without it, the time at a station is the queue in front of the machine and the work on it, together. With it, they come apart, and you can see whether a station is slow or just busy.
What it gives you
Every read becomes an event: this job, this station, this time, in or out. In EPCIS, the GS1 standard for these records, in and out are the business steps arriving and departing from the Core Business Vocabulary. Work starting has no standard step, so you name it yourself.
Subtract consecutive events and you get the two numbers that matter on a floor: how long a job spent at each station, and how long it waited between them. Do that for every job for a week and the station with the longest wait in front of it is your bottleneck. You don’t have to guess or ask.
What it won’t do
It won’t count parts. The tag says the bin arrived. It doesn’t say whether there are 48 shafts in it or 47. That’s still a person at the station, or a scale.
It only knows what passed a read point. A bin carried round the side of a gate, or a card left in someone’s pocket, is a missing line in the history. Desk pads depend on the card actually going down on the desk. That’s a habit, and it takes a week or two to stick.
What it assumes
One tag per job, on whatever carries the job, and the tag comes back when the job ships. So you buy tags for the jobs on the floor at once, plus a quarter spare for sleeves that go missing. An inlay costs 5 to 8 rupees. A steel trolley needs an on-metal tag, about 60.
One reader per station. A gate’s two antennas share a fixed reader with several ports; a desk has its own small one. IoTReady’s RFID reader comes as Long Range for gates and Short Range for desks. Range isn’t what you’re short of here. The Long Range module is rated to 15 m, you’ll see about 5 on a real floor, and a gate wants less than that, turned down so it doesn’t read the trolley parked beside it.
The example day for order 4417 is made up, with the same times as the film. Your own times will come from your own floor.